| Phase | Three Phase, Single Phase |
| Cooling Type | Oil cooled, Dry Type, Air Cooled |
| Automation Grade | Automatic |
| Surge Protection | With Surge Protection |
| Control Type | Micro controller, Digital controller |
| Type | Automatic |
| Input Voltage | 160 V - 260 V AC, 300 V - 460 V AC |
| Output Voltage | 225 V - 230 V AC, 400 V - 415 V AC |
| Product Type | Digital, Indoor |
| Is It ISO Certified | ISO Certified |
| Current Type | AC |
| Is It Over Volt Protection | Available |
| Is It Portable | Portable |
| Body Material | Steel |
| Condition | New |
| Frequency | 50 Hz |
| Type | Single Phase | 3Ø Balance Load | 3Ø Unbalance Load |
| Input Voltage Range | 160 V- 260 V AC | 300 V - 460 V AC | |
| KVA Rating Capacity | 0.5, 1, 2, 3.15, 5, 8, 10, 16, 20, 25, 31, 5, 40, 50, 100, 125, 150, 200, 300 350 KVA | 3, 5, 10, 15, 20, 25, 30, 40, 50, 80, 100, 125, 150, 200, 300, 400, 500, 600, 1000 upto 2000 KVA | |
| Output Voltage Rated Operating Frequency | 225V - 230V AC Settable 50 HZ | 400V - 415V AC Settable 50 HZ | |
| Metering | 72 mm to 100 mm Dial Accuracy 1.5 Voltmeter with Selector switch to indicate Input and output Voltage. | ||
| Input / Output Connection Up to KVA Over 2 KVA | 15 Amps. Plug and socket Terminal for input-output Connections | ||
| Indicator | Mains 'on' pilot lamp on front panel, Low and High limit indicator of Dimmer on the front panel. | Mains pilot lamp on each phase low and High limit indicator of Dimmer on the front panel. Oil indicator will there | |
| Manual Control | Provision for manual control of output. | Provision for manual control of output on each phase. | |
| Cooling Air Cooling Oil Cooling | 0.5 - 10 KVA 15 KVA - 350 KVA | 2.5 - 30 KVA 40 KVA - 20000 KVA | |
| Output Voltage Regulation | ± 1% | ± 1% | |
| Rate of Correction | 20 Volts / Second | 30 Volts / Second | |
| Efficiency | More than 90% | ||
| Duty Cycle | 100% | ||
| Specifications | IS : 9815 (Part 1) / 1994 (Reaffirmed 1999) | ||
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
| Phase | Three Phase |
| Cooling Type | Oil cooled |
| Rated Capacity | 100 KVA |
| Usage/Application | Industrial |
| Input Voltage | 300-460 v |
View Complete details
Product Brochure
| Phase | Single Phase |
| Cooling Type | Air Cooled |
| Usage/Application | Industrial |
| Brand | Sterco |
| Control Type | Digital controller |
View Complete details
Product Brochure
| Phase | Single Phase |
| Brand | Sterco |
| Automation Grade | Automatic |
| Control Type | Digital |
| I Deal In | New Only |
| Type | Single Phase | 3Ø Balance Load | 3Ø Unbalance Load |
| Input Voltage Range | 160 V- 260 V AC | 300 V - 460 V AC | |
| KVA Rating Capacity |
0.5, 1, 2, 3.15, 5, 8, 10, 16, 20, 25, 31, 5, 40, 50, 100, 125, 150, 200, 300 350 KVA | 3, 5, 10, 15, 20, 25, 30, 40, 50, 80, 100, 125, 150, 200, 300, 400, 500, 600, 1000 upto 2000 KVA | |
| Output Voltage Rated Operating Frequency |
225V - 230V AC Settable 50 HZ |
400V - 415V AC Settable 50 HZ |
|
| Metering | 72 mm to 100 mm Dial Accuracy 1.5 Voltmeter with Selector switch to indicate Input and output Voltage. | ||
| Input / Output Connection Up to KVA Over 2 KVA |
15 Amps. Plug and socket Terminal for input-output Connections |
||
| Indicator | Mains 'on' pilot lamp on front panel, Low and High limit indicator of Dimmer on the front panel. | Mains pilot lamp on each phase low and High limit indicator of Dimmer on the front panel. Oil indicator will there | |
| Manual Control | Provision for manual control of output. | Provision for manual control of output on each phase. | |
| Cooling Air Cooling Oil Cooling |
0.5 - 10 KVA 15 KVA - 350 KVA |
2.5 - 30 KVA 40 KVA - 20000 KVA |
|
| Output Voltage Regulation |
± 1% | ± 1% | |
| Rate of Correction | 20 Volts / Second | 30 Volts / Second | |
| Efficiency | More than 90% | ||
| Duty Cycle | 100% | ||
| Specifications | IS : 9815 (Part 1) / 1994 (Reaffirmed 1999) | ||
View Complete details
View Complete details
| Cooling Type | Oil cooled |
| Usage/Application | All |
| Brand | STERCO |
| Control Type | Digital controller |
| Automatic Grade | Automatic |
| Phase | Single Phase, Three Phase |
| Input Voltage | 160 V - 260 V AC, 300 V - 460 V AC |
| Output Voltage | 225 V - 230 V AC, 400 V - 415 V AC |
| Frequency | 50 Hz |
| Type | Single Phase | 3Ø Balance Load | 3Ø Unbalance Load |
| Input Voltage Range | 160 V- 260 V AC | 300 V - 460 V AC | |
| KVA Rating Capacity | 0.5, 1, 2, 3.15, 5, 8, 10, 16, 20, 25, 31, 5, 40, 50, 100, 125, 150, 200, 300 350 KVA | 3, 5, 10, 15, 20, 25, 30, 40, 50, 80, 100, 125, 150, 200, 300, 400, 500, 600, 1000 upto 2000 KVA | |
| Output Voltage Rated Operating Frequency | 225V - 230V AC Settable 50 HZ | 400V - 415V AC Settable 50 HZ | |
| Metering | 72 mm to 100 mm Dial Accuracy 1.5 Voltmeter with Selector switch to indicate Input and output Voltage. | ||
| Input / Output Connection Up to KVA Over 2 KVA | 15 Amps. Plug and socket Terminal for input-output Connections | ||
| Indicator | Mains 'on' pilot lamp on front panel, Low and High limit indicator of Dimmer on the front panel. | Mains pilot lamp on each phase low and High limit indicator of Dimmer on the front panel. Oil indicator will there | |
| Manual Control | Provision for manual control of output. | Provision for manual control of output on each phase. | |
| Cooling Air Cooling Oil Cooling | 0.5 - 10 KVA 15 KVA - 350 KVA | 2.5 - 30 KVA 40 KVA - 20000 KVA | |
| Output Voltage Regulation | ± 1% | ± 1% | |
| Rate of Correction | 20 Volts / Second | 30 Volts / Second | |
| Efficiency | More than 90% | ||
| Duty Cycle | 100% | ||
| Specifications | IS : 9815 (Part 1) / 1994 (Reaffirmed 1999) | ||
View Complete details
Product Brochure
| Phase | Three Phase |
| Color | Green |
| Output Voltage | 225V - 230V AC |
| Input Voltage Range | 160 V- 260 V AC |
| Rating Capacity | 0.5, 2, 3.15, 10, 100, 150, 125, 5, 50, 300 &350 KVA, 20, 31, 8, 1, 25, 16, 40, 200 |
| Frequency | 50 Hz |
| Metering | 72 mm to 100 mm Dial Accuracy 1.5 Voltmeter with Selector switch to indicate Input and output Voltag |
| Input / Output Connection Upto KVA Over 2 KVA | 15 Amps. Plug and socket Terminal for input & output Connections |
| Output Voltage Regulation | +- 1% |
| Rate of Correction | 20 Volts / Second |
| Efficiency | More than 90% |